S3700 Series Iiswitshi Enterprise

Kwi-Fast Ethernet yokutshintsha ngaphezulu kobhedu olujijekileyo, iHuawei's S3700 Series idibanisa ukuthembeka okungqiniweyo kunye nomzila owomeleleyo, ukhuseleko, kunye neempawu zolawulo kwi-compact, i-eneji eyonga amandla.

Ukusasazwa kwe-VLAN eguquguqukayo, amandla e-PoE, imisebenzi ebanzi yomzila, kunye nokukwazi ukufudukela kwinethiwekhi ye-IPv6 yokunceda abathengi bamashishini ukwakha i-IT yesizukulwana esilandelayo.

Khetha imodeli ye-Standard (SI) ye-L2 kunye ne-L3 esisiseko yokutshintsha;Iimodeli eziphuculweyo (EI) zixhasa i-IP multicasting kunye neeprothokholi zomzila ezintsonkothileyo (OSPF, IS-IS, BGP).

Inkcazo

Kwi-Fast Ethernet yokutshintsha ngaphezulu kobhedu olujijekileyo, iHuawei's S3700 Series idibanisa ukuthembeka okungqiniweyo kunye nomzila owomeleleyo, ukhuseleko, kunye neempawu zolawulo kwi-compact, i-eneji eyonga amandla.
Ukusasazwa kwe-VLAN eguquguqukayo, amandla e-PoE, imisebenzi ebanzi yomzila, kunye nokukwazi ukufudukela kwinethiwekhi ye-IPv6 yokunceda abathengi bamashishini ukwakha i-IT yesizukulwana esilandelayo.
Khetha imodeli ye-Standard (SI) ye-L2 kunye ne-L3 esisiseko yokutshintsha;Iimodeli eziphuculweyo (EI) zixhasa i-IP multicasting kunye neeprothokholi zomzila ezintsonkothileyo (OSPF, IS-IS, BGP).

Ingcaciso yeMveliso

 

I-S3700-28TP-SI-DC Mainframe (24 Ethernet 10/100 port, 2 Gig SFP, kunye ne-2-purpose-purpose 10/100/1,000 okanye SFP, DC -48V)
I-S3700-28TP-EI-DC Mainframe (24 Ethernet 10/100 izibuko, i-2 Gig SFP, kunye ne-2-injongo ezimbini 10/100/1,000 okanye i-SFP, DC -48V)
I-S3700-52P-PWR-EI Mainframe (48 Ethernet 10/100 port, 4 Gig SFP, PoE +, Dual Slots of power, Ngaphandle kweModyuli yaMandla)
I-S3700-28TP-PWR-EI Mainframe (24 Ethernet 10/100 izibuko, i-2 Gig SFP, kunye ne-2-injongo ezimbini 10/100/1,000 okanye i-SFP, i-PoE +, i-Dual Slots yamandla, Ngaphandle kweModyuli yaMandla)
I-S3700-28TP-EI-AC Mainframe (24 Ethernet 10/100 izibuko, i-2 Gig SFP, kunye ne-2-injongo ezimbini 10/100/1,000 okanye i-SFP, i-AC 110/220V)
I-S3700-28TP-EI-24S-AC Mainframe (24 FE SFP, 2 Gig SFP kunye ne-2-injongo ezimbini 10/100/1,000 okanye SFP, AC 110/220V)
I-S3700-28TP-EI-MC-AC Mainframe (24 Ethernet 10/100 izibuko, i-2 Gig SFP, kunye ne-2-injongo ezimbini 10/100/1,000 okanye i-SFP, izibuko ze-2 MC, i-AC 110/220V)
I-S3700-52P-SI-AC Mainframe (48 Ethernet 10/100 izibuko, 4 Gig SFP, AC 110/220V)
I-S3700-52P-EI-48S-AC Mainframe (48 FE SFP, 4 Gig SFP, AC 110/220V)
I-S3700-28TP-SI-AC Mainframe (24 Ethernet 10/100 izibuko, i-2 Gig SFP, kunye ne-2-injongo ezimbini 10/100/1,000 okanye i-SFP, i-AC 110/220V)
I-S3700-52P-EI-24S-AC Mainframe (24 Ethernet 10/100 izibuko, 24 FE SFP, 4 Gig SFP, AC 110/220V)
S3700-52P-EI-AC Mainframe (48 Ethernet 10/100 izibuko, 4 Gig SFP, AC 110/220V)
I-S3700-52P-PWR-SI Mainframe (48 Ethernet 10/100 izibuko, i-4 Gig SFP, i-PoE +, i-Dual Slots of Power, kubandakanywa i-Single 500W AC Power)
I-S3700-28TP-PWR-SI Mainframe (24 Ethernet 10/100 port, 2 Gig SFP, kunye ne-2-purpose-purpose 10/100/1,000 okanye SFP, PoE +, Dual Slots of Power, Kubandakanya iSingle 500W AC Power)
500W AC Power Module

Iinkcukacha

 

Iinkcukacha S3700-SI S3700-EI
Ukutshintsha Umthamo 64 Gbit/s 64 Gbit/s
Ukuhanjiswa koMsebenzi 9.6 Mpps/13.2 Mpps
Inkcazo yePort Downlink: 24/48 x 100 Base-TX Ethernet amazibuko Downlink: 24/48 x 100 Base-TX Ethernet amazibuko
I-Uplink: I-4 x izibuko ze-GE I-Uplink: I-4 x izibuko ze-GE
Ukuthembeka I-RRPP, i-Smart Link, kunye ne-SEP I-RRPP, i-Smart Link, kunye ne-SEP
I-STP, i-RSTP, kunye ne-MSTP I-STP, i-RSTP, kunye ne-MSTP
BFD
IP Routing Indlela engatshintshiyo, i-RIPv1, i-RIPv2, kunye ne-ECMP Indlela engatshintshiyo, i-RIPv1, i-RIPv2, kunye ne-ECMP
OSPF, IS-IS, kunye ne-BGP
IPv6 Iimpawu Ukufunyanwa kommelwane (ND) Ukufunyanwa kommelwane (ND)
Indlela ye-MTU (PMTU) Indlela ye-MTU (PMTU)
IPv6 ping, IPv6 tracert, kunye ne IPv6 Telnet IPv6 ping, IPv6 tracert, kunye ne IPv6 Telnet
Itonela iqwalaselwe ngesandla Itonela iqwalaselwe ngesandla
6to4 itonela 6to4 itonela
Itonela ye-ISAPA Itonela ye-ISAPA
ACLs esekwe kumthombo IPv6 idilesi, indawo IPv6 idilesi, Layer 4 izibuko, okanye uhlobo protocol. ACLs esekwe kumthombo IPv6 idilesi, indawo IPv6 idilesi, Layer 4 izibuko, okanye uhlobo protocol.
I-MLD v1/v2 ihlola I-MLD v1/v2 ihlola
Multicast 1K amaqela e-multicast 1K amaqela e-multicast
IGMP v1/v2/v3 snooping kunye ne-IGMP ikhefu elikhawulezayo IGMP v1/v2/v3 snooping kunye ne-IGMP ikhefu elikhawulezayo
I-Multicast VLAN kunye nokuphindaphindwa kwe-multicast phakathi kweVLAN I-Multicast VLAN kunye nokuphindaphindwa kwe-multicast phakathi kweVLAN
I-Multicast load balancing phakathi kwamazibuko amalungu esiqwini I-Multicast load balancing phakathi kwamazibuko amalungu esiqwini
Usasazo oluninzi olulawulekayo Usasazo oluninzi olulawulekayo
Iinkcukacha-manani zetrafikhi esekwe kwizibuko Iinkcukacha-manani zetrafikhi esekwe kwizibuko
QoS/ACL Ireyithi yokunciphisa iipakethi ezithunyelwe kwaye zamkelwe ngojongano Ireyithi yokunciphisa iipakethi ezithunyelwe kwaye zamkelwe ngojongano
Ukwalathisa ipakethi kwakhona Ukwalathisa ipakethi kwakhona
Ubupolisa obusekwe kwizibuko lwezithuthi kunye nenqanaba ezibini ngemibala emithathu yeCAR Ubupolisa obusekwe kwizibuko lwezithuthi kunye nenqanaba ezibini ngemibala emithathu yeCAR
Imigca esibhozo kwizibuko ngalinye Imigca esibhozo kwizibuko ngalinye
I-WRR, DRR, SP, WRR + SP, kunye ne-DRR + SP ishedyuli yokucwangcisa umgca I-WRR, DRR, SP, WRR + SP, kunye ne-DRR + SP ishedyuli yokucwangcisa umgca
Ukumakishwa kwakhona kweprayorithi ye-802.1p kunye neprayorithi ye-DSCP Ukumakishwa kwakhona kweprayorithi ye-802.1p kunye neprayorithi ye-DSCP
Ukuhluza ipakethe kuMaleko 2 ukuya ku-4, ukuhluza izakhelo ezingasebenziyo ngokusekwe kumthombo wedilesi ye-MAC, idilesi ye-MAC yokusingwa, idilesi ye-IP yomthombo, idilesi ye-IP yendawo ekuyiwa kuyo, inombolo yezibuko, uhlobo lomthetho, kunye ne-VLAN ID. Ukuhluza ipakethe kuMaleko 2 ukuya ku-4, ukuhluza izakhelo ezingasebenziyo ngokusekwe kumthombo wedilesi ye-MAC, idilesi ye-MAC yokusingwa, idilesi ye-IP yomthombo, idilesi ye-IP yendawo ekuyiwa kuyo, inombolo yezibuko, uhlobo lomthetho, kunye ne-VLAN ID.
Ireyithi yokunciphisa kumgca ngamnye kunye nokubunjwa kwetrafikhi kumazibuko Ireyithi yokunciphisa kumgca ngamnye kunye nokubunjwa kwetrafikhi kumazibuko
Ukhuseleko kunye noFikelelo Ulawulo lwamalungelo omsebenzisi kunye nokhuseleko lokugqitha Ulawulo lwamalungelo omsebenzisi kunye nokhuseleko lokugqitha
Ukhuselo lohlaselo lwe-DoS, ukhuselo lohlaselo lwe-ARP, kunye nokhuselo lohlaselo lwe-ICMP Ukhuselo lohlaselo lwe-DoS, ukhuselo lohlaselo lwe-ARP, kunye nokhuselo lohlaselo lwe-ICMP
Ukubophelela kwedilesi ye-IP, idilesi ye-MAC, ujongano, kunye neVLAN Ukubophelela kwedilesi ye-IP, idilesi ye-MAC, ujongano, kunye neVLAN
Ukwahlulwa kwezibuko, ukhuseleko lwezibuko, kunye ne-MAC encangathi Ukwahlulwa kwezibuko, ukhuseleko lwezibuko, kunye ne-MAC encangathi
Ungeniso lwedilesi ye-MAC yaseBlackhole Ungeniso lwedilesi ye-MAC yaseBlackhole
Ukunciphisa inani leedilesi ezifundiweyo ze-MAC Ukunciphisa inani leedilesi ezifundiweyo ze-MAC
802.1x ukuqinisekiswa kunye nomda kwinani labasebenzisi kwi-interface 802.1x ukuqinisekiswa kunye nomda kwinani labasebenzisi kwi-interface
Uqinisekiso lwe-AAA, uqinisekiso lwe-RADIUS, uqinisekiso lwe-HWTACACS, kunye ne-NAC Uqinisekiso lwe-AAA, uqinisekiso lwe-RADIUS, uqinisekiso lwe-HWTACACS, kunye ne-NAC
I-SSH v2.0 I-SSH v2.0
Ukhuselo lweCPU Ukhuselo lweCPU
Uluhlu olumnyama kunye noluhlu olumhlophe Uluhlu olumnyama kunye noluhlu olumhlophe
Iseva ye-DHCP, i-DHCP relay, i-DHCP snooping, kunye nokhuseleko lwe-DHCP Iseva ye-DHCP, i-DHCP relay, i-DHCP snooping, kunye nokhuseleko lwe-DHCP
UKhuseleko lweSurgery Amandla okukhusela amazibuko eenkonzo: 7 kV Amandla okukhusela amazibuko eenkonzo: 7 kV
Ulawulo kunye noLondolozo iStack iStack
Ugqithiso olunyanzelweyo lwe-MAC (MFF) Ugqithiso olunyanzelweyo lwe-MAC (MFF)
Ubumbeko kunye nokugcinwa kude usebenzisa iTelnet Ubumbeko kunye nokugcinwa kude usebenzisa iTelnet
Uqwalaselo oluzenzekelayo Uqwalaselo oluzenzekelayo
Uvavanyo lwentambo ebonakalayo Uvavanyo lwentambo ebonakalayo
I-Ethernet OAM (IEEE 802.3ah kunye ne-802.1ag) I-Ethernet OAM (IEEE 802.3ah kunye ne-802.1ag)
I-alam yokucima umbane wokufa (S3700-28TP-EI-MC-AC) I-alam yokucima umbane wokufa (S3700-28TP-EI-MC-AC)
I-SNMP v1/v2c/v3 kunye ne-RMON I-SNMP v1/v2c/v3 kunye ne-RMON
I-MUX VLAN kunye ne-GVRP I-MUX VLAN kunye ne-GVRP
I-eSight kunye ne-NMS yewebhu I-eSight kunye ne-NMS yewebhu
I-SSH v2 I-SSH v2
Ukutya umbane S3700-28TP-SI < 20W S3700-28TP-EI < 20W
S3700-52P-SI < 38W S3700-28TP-EI-MC < 20W
S3700-28TP-EI-24S < 52W
S3700-52P-EI < 38W
S3700-52P-EI-24S < 65W
S3700-52P-EI-48S < 90W
S3700-28TP-PWR-EI < 818W (PoE: 740W)
S3700-52P-PWR-EI < 880W (PoE: 740W)
Ukusebenzisana I-VLAN-based Spanning Tree (VBST) (isebenzisana ne-PVST, i-PVST+, kunye ne-RPVST)
Unxulumano loNxibelelwano lweProtocol (LNP) (efana ne-DTP)
I-VLAN Central Management Protocol (VCMP) (ifana ne-VTP)
Ngezatifikethi ezineenkcukacha zokusebenzisana kunye neengxelo zovavanyo, cofa APHA.

Khetha iHuawei S3700 Series Ethernet Iiswitshi zoxinaniso oluphezulu 100 Mbit/s L2 kunye nofikelelo lwe-L3 kunye nokutshintsha ngokudibanisa

  • Isebenzisa i-software ye-Huawei's Versatile Routing Platform (VRP).
  • Ukubonwa okukrelekrele ngetekhnoloji ye-iStack yeHuawei
  • I-Smart Link kunye neProtocol yokuKhusela iRingi ngokukhawuleza (RRPP) iqinisekisa ukuthembeka kwenethiwekhi
  • Izaziso zokufa kwemiyalezo yokuphelelwa ngamandla
  • Inkxaso yeeprothokholi zomzila ze-IPv6 eziquka i-RIPng kunye ne-OSPFv3

Khuphela

  • Huawei-s3700-series-switches-datasheet
    Huawei-s3700-series-switches-datasheet