Ma Swichi a Makampani a S3700 Series
Pakusintha kwa Fast Ethernet pamwamba pa mkuwa wopindika, Huawei's S3700 Series imaphatikiza kudalirika kotsimikizika ndi njira yolimba, chitetezo, ndi magwiridwe antchito mu switch yaying'ono komanso yosagwiritsa ntchito mphamvu zambiri.
Kukhazikitsa kwa VLAN kosinthasintha, kuthekera kwa PoE, ntchito zonse zoyendetsera, komanso kuthekera kosamukira ku netiweki ya IPv6 zimathandiza makasitomala amakampani kupanga ma netiweki a IT a m'badwo watsopano.
Sankhani mitundu ya Standard (SI) ya L2 ndi basic L3 switching; Mitundu ya Enhanced (EI) imathandizira IP multicasting ndi ma protocol ovuta kwambiri a routing (OSPF, IS-IS, BGP).
Pakusintha kwa Fast Ethernet pamwamba pa mkuwa wopindika, Huawei's S3700 Series imaphatikiza kudalirika kotsimikizika ndi njira yolimba, chitetezo, ndi magwiridwe antchito mu switch yaying'ono komanso yosagwiritsa ntchito mphamvu zambiri.
Kukhazikitsa kwa VLAN kosinthasintha, kuthekera kwa PoE, ntchito zonse zoyendetsera, komanso kuthekera kosamukira ku netiweki ya IPv6 zimathandiza makasitomala amakampani kupanga ma netiweki a IT a m'badwo watsopano.
Sankhani mitundu ya Standard (SI) ya L2 ndi basic L3 switching; Mitundu ya Enhanced (EI) imathandizira IP multicasting ndi ma protocol ovuta kwambiri a routing (OSPF, IS-IS, BGP).
Mafotokozedwe Akatundu
S3700-28TP-SI-DC Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, DC -48V) S3700-28TP-EI-DC Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, DC -48V) S3700-52P-PWR-EI Mainframe (madoko 48 a Ethernet 10/100, 4 Gig SFP, PoE+, Dual Slots of power, Popanda Power Module) S3700-28TP-PWR-EI Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, PoE+, Ma Dual Slots a mphamvu, Popanda Power Module) S3700-28TP-EI-AC Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, AC 110/220V) S3700-28TP-EI-24S-AC Mainframe (24 FE SFP, 2 Gig SFP ndi 2 zogwirira ntchito ziwiri 10/100/1,000 kapena SFP, AC 110/220V) S3700-28TP-EI-MC-AC Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, madoko awiri a MC, AC 110/220V) S3700-52P-SI-AC Mainframe (madoko 48 a Ethernet 10/100, 4 Gig SFP, AC 110/220V) S3700-52P-EI-48S-AC Mainframe (48 FE SFP, 4 Gig SFP, AC 110/220V) S3700-28TP-SI-AC Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi awiri okhala ndi ntchito ziwiri 10/100/1,000 kapena SFP, AC 110/220V) S3700-52P-EI-24S-AC Mainframe (madoko 24 a Ethernet 10/100, 24 FE SFP, 4 Gig SFP, AC 110/220V) S3700-52P-EI-AC Mainframe (madoko 48 a Ethernet 10/100, 4 Gig SFP, AC 110/220V) S3700-52P-PWR-SI Mainframe (madoko 48 a Ethernet 10/100, 4 Gig SFP, PoE+, Dual Slots of Power, Kuphatikizapo Single 500W AC Power) S3700-28TP-PWR-SI Mainframe (madoko 24 a Ethernet 10/100, ma Gig SFP awiri, ndi ma dual-purpose awiri 10/100/1,000 kapena SFP, PoE+, Dual Slots of Power, kuphatikiza Single 500W AC Power) 500W AC Power Module
Mafotokozedwe
Mafotokozedwe S3700-SI S3700-EI Kusintha Mphamvu 64 Gbit/s 64 Gbit/s Kutumiza Magwiridwe Ntchito 9.6 Mpps/13.2 Mpps Kufotokozera kwa Doko Downlink: Madoko a Ethernet a 24/48 x 100 Base-TX Downlink: Madoko a Ethernet a 24/48 x 100 Base-TX Uplink: Madoko 4 a GE Uplink: Madoko 4 a GE Kudalirika RRPP, Smart Link, ndi SEP RRPP, Smart Link, ndi SEP STP, RSTP, ndi MSTP STP, RSTP, ndi MSTP BFD Kutumiza kwa IP Njira yosasinthasintha, RIPv1, RIPv2, ndi ECMP Njira yosasinthasintha, RIPv1, RIPv2, ndi ECMP OSPF, IS-IS, ndi BGP Zinthu za IPv6 Kupeza Anthu Oyandikana Nawo (ND) Kupeza Anthu Oyandikana Nawo (ND) Njira ya MTU (PMTU) Njira ya MTU (PMTU) IPv6 ping, IPv6 tracert, ndi IPv6 Telnet IPv6 ping, IPv6 tracert, ndi IPv6 Telnet Ngalande yokonzedwa pamanja Ngalande yokonzedwa pamanja ngalande ya 6to4 ngalande ya 6to4 Ngalande ya ISATAP Ngalande ya ISATAP Ma ACL otengera adilesi ya IPv6 yochokera, adilesi ya IPv6 yopita, madoko a Layer 4, kapena mtundu wa protocol Ma ACL otengera adilesi ya IPv6 yochokera, adilesi ya IPv6 yopita, madoko a Layer 4, kapena mtundu wa protocol Kuyang'ana kwa MLD v1/v2 Kuyang'ana kwa MLD v1/v2 Kusewera kwamitundu yambiri Magulu a 1K multicast Magulu a 1K multicast Kuyang'ana IGMP v1/v2/v3 ndi kuchoka mwachangu kwa IGMP Kuyang'ana IGMP v1/v2/v3 ndi kuchoka mwachangu kwa IGMP Ma VLAN ambiri ojambulidwa ndi ma multicast ndi ma multicast ojambulidwa pakati pa ma VLAN Ma VLAN ambiri ojambulidwa ndi ma multicast ndi ma multicast ojambulidwa pakati pa ma VLAN Kulinganiza katundu wambiri pakati pa madoko a mamembala a trunk Kulinganiza katundu wambiri pakati pa madoko a mamembala a trunk Kuwongolera kwa multicast Kuwongolera kwa multicast Ziwerengero za magalimoto oyendetsedwa ndi ma doko ambiri Ziwerengero za magalimoto oyendetsedwa ndi ma doko ambiri QoS/ACL Kuchepetsa mitengo pa mapaketi otumizidwa ndi kulandiridwa ndi mawonekedwe Kuchepetsa mitengo pa mapaketi otumizidwa ndi kulandiridwa ndi mawonekedwe Kutumizanso paketi Kutumizanso paketi Apolisi oyendera magalimoto omwe ali padoko komanso CAR yamitundu iwiri Apolisi oyendera magalimoto omwe ali padoko komanso CAR yamitundu iwiri Mizere isanu ndi itatu pa doko lililonse Mizere isanu ndi itatu pa doko lililonse Ma algorithms a WRR, DRR, SP, WRR + SP, ndi DRR + SP okonza mndandanda wa mizere Ma algorithms a WRR, DRR, SP, WRR + SP, ndi DRR + SP okonza mndandanda wa mizere Kulembanso chizindikiro cha 802.1p priority ndi DSCP priority Kulembanso chizindikiro cha 802.1p priority ndi DSCP priority Kusefa mapaketi pa Zigawo 2 mpaka 4, kusefa mafelemu osavomerezeka kutengera adilesi ya MAC yoyambira, adilesi ya MAC yoyambira, adilesi ya IP yoyambira, adilesi ya IP yoyambira, nambala ya doko, mtundu wa protocol, ndi VLAN ID Kusefa mapaketi pa Zigawo 2 mpaka 4, kusefa mafelemu osavomerezeka kutengera adilesi ya MAC yoyambira, adilesi ya MAC yoyambira, adilesi ya IP yoyambira, adilesi ya IP yoyambira, nambala ya doko, mtundu wa protocol, ndi VLAN ID Kuchepetsa mitengo pamzere uliwonse ndi kusintha kwa magalimoto pamadoko Kuchepetsa mitengo pamzere uliwonse ndi kusintha kwa magalimoto pamadoko Chitetezo ndi Kufikira Kusamalira mwayi wa ogwiritsa ntchito ndi chitetezo cha mawu achinsinsi Kusamalira mwayi wa ogwiritsa ntchito ndi chitetezo cha mawu achinsinsi Chitetezo cha DoS kuukira, chitetezo cha ARP kuukira, ndi chitetezo cha ICMP kuukira Chitetezo cha DoS kuukira, chitetezo cha ARP kuukira, ndi chitetezo cha ICMP kuukira Kulumikizana kwa adilesi ya IP, adilesi ya MAC, mawonekedwe, ndi VLAN Kulumikizana kwa adilesi ya IP, adilesi ya MAC, mawonekedwe, ndi VLAN Kupatula madoko, chitetezo cha madoko, ndi MAC yomata Kupatula madoko, chitetezo cha madoko, ndi MAC yomata Ma adilesi a Blackhole MAC Ma adilesi a Blackhole MAC Malire pa chiwerengero cha maadiresi a MAC omwe aphunziridwa Malire pa chiwerengero cha maadiresi a MAC omwe aphunziridwa Kutsimikizira kwa 802.1x ndi malire pa chiwerengero cha ogwiritsa ntchito pa mawonekedwe Kutsimikizira kwa 802.1x ndi malire pa chiwerengero cha ogwiritsa ntchito pa mawonekedwe Kutsimikizira kwa AAA, kutsimikizira kwa RADIUS, kutsimikizira kwa HWTACACS, ndi NAC Kutsimikizira kwa AAA, kutsimikizira kwa RADIUS, kutsimikizira kwa HWTACACS, ndi NAC SSH v2.0 SSH v2.0 Chitetezo cha CPU Chitetezo cha CPU Mndandanda wakuda ndi mndandanda woyera Mndandanda wakuda ndi mndandanda woyera Seva ya DHCP, DHCP relay, DHCP snooping, ndi chitetezo cha DHCP Seva ya DHCP, DHCP relay, DHCP snooping, ndi chitetezo cha DHCP Chitetezo cha Kuphulika Mphamvu yoteteza madoko operekera chithandizo: 7 kV Mphamvu yoteteza madoko operekera chithandizo: 7 kV Kuyang'anira ndi Kusamalira iStack iStack Kutumiza Kwa MAC Mokakamizidwa (MFF) Kutumiza Kwa MAC Mokakamizidwa (MFF) Kukonza ndi kukonza patali pogwiritsa ntchito Telnet Kukonza ndi kukonza patali pogwiritsa ntchito Telnet Kukhazikitsa Kokha Kukhazikitsa Kokha Mayeso a chingwe chongopeka Mayeso a chingwe chongopeka Ethernet OAM (IEEE 802.3ah ndi 802.1ag) Ethernet OAM (IEEE 802.3ah ndi 802.1ag) Alamu yozimitsa mpweya (S3700-28TP-EI-MC-AC) Alamu yozimitsa mpweya (S3700-28TP-EI-MC-AC) SNMP v1/v2c/v3 ndi RMON SNMP v1/v2c/v3 ndi RMON MUX VLAN ndi GVRP MUX VLAN ndi GVRP eSight ndi NMS ya pa intaneti eSight ndi NMS ya pa intaneti SSH v2 SSH v2 Kugwiritsa Ntchito Mphamvu S3700-28TP-SI < 20W S3700-28TP-EI < 20W S3700-52P-SI < 38W S3700-28TP-EI-MC < 20W S3700-28TP-EI-24S < 52W S3700-52P-EI < 38W S3700-52P-EI-24S < 65W S3700-52P-EI-48S < 90W S3700-28TP-PWR-EI < 818W (PoE: 740W) S3700-52P-PWR-EI < 880W (PoE: 740W)
Kugwirizana Mtengo Wopachika Mafayilo (VBST) wochokera ku VLAN (wogwirizana ndi PVST, PVST+, ndi RPVST) Njira Yolumikizirana Yolumikizirana (LNP) (yofanana ndi DTP) VLAN Central Management Protocol (VCMP) (yofanana ndi VTP) Kuti mupeze ziphaso zatsatanetsatane zokhudzana ndi mgwirizano ndi malipoti oyesera, dinani PANO.
Sankhani ma Switch a Huawei S3700 Series Ethernet kuti muzitha kugwiritsa ntchito ma 100 Mbit/s L2 ndi L3 komanso kusinthana ma aggregation.



