Ngwaahịa
-
Kaadị NMS
NMS (Network Management System) bụ ngwanrọ njikwa netwọkụ nke Shenzhen HUANET Technology Co., Ltd. mepụtara ma mepụta iji nyochaa ikpo okwu nnyefe nkewa ogologo oge HUA6000 & HUA6800 usoro nkwukọrịta ogologo oge. Njikọ ọrụ eserese ya dị mfe ma dị mfe nghọta, ma nwee ezigbo ndidi maka mmejọ. Ọrụ na mmezi, dị mfe ma dị mfe iji. Site na ọzụzụ nwa oge maka ndị ọrụ, enwere ike itinye sistemụ ngwa ahụ n'ọrụ nkịtị.
NMS nwere ọrụ dịka njikwa ngwaọrụ, njikwa njikọ, njikwa ndekọ, njikwa nchekwa, ngosipụta topology, njikwa mmejọ na ebe mmejọ. Ngwanrọ njikwa netwọk NMS na-eme njikwa data etiti, si otú a na-ahụ na izi ezi, nchekwa, na ịdị iche nke data, enwere ike imelite ya n'oge; sistemụ ahụ nwere ike ime ajụjụ topology netwọk dịka mmekọrịta topology edobere, dị ka ngwaọrụ ajụjụ, ụzọ agbụ ajụjụ, ebe mmejọ, wdg. Nchekwa data bụ akụkụ dị mkpa nke sistemụ. Sistemụ ahụ na-eji ụzọ nkwado ndabere data pụrụ iche iji kwado data emechiri emechi na akpaghị aka na mgbe niile na-enweghị ọrụ ọ bụla site n'aka onye ọrụ iji hụ na ọrụ sistemụ ahụ na-aga n'ihu na nke a pụrụ ịtụkwasị obi na ya.
-
Kaadị DWDM MUX/DEMUX 40CH (AAWG)
HUA6000-AAWG40 sitere na HUANET bụ njikọta passiveForty-Cihe njikwa 100GHz DWDM multiplexer na de-multiplexer (MUX & DEMUX). Ọ na-ejikọta ọwa grid DWDM ITU 100GHZ ọkọlọtọ 21 ruo 60, naana-adabere na chassis 1U,Chassis 2U naChassis 5U, na-eji oghere ọrụ abụọ.
-
400G OTN Muxponder 4x100G na-agbakọta na 400G
Ihe nnyefe 400G Muxponder na-akwado interface ndị ahịa QSFP28 anọ na otu interface CFP2 n'akụkụ aka nri iji kwado nnyefe data nnukwu ọka 400Gbps nke otu ọwa. Teknụzụ kachasị elu nke ụlọ ọrụ ahụ na teknụzụ nhazi njehie FEC na-eme ka nnyefe arụmọrụ dị elu na ogologo anya dị elu. -
200G Muxponder 2x100G na-agbakọta na 200G
Ihe nnyefe 200G Muxponder na-akwado interface abụọ nke ndị ahịa QSFP28 na otu interface CFP2 n'akụkụ aka nri iji kwado nnyefe data nnukwu ọka 200Gbps nke otu ọwa. Teknụzụ kachasị elu nke ụlọ ọrụ ahụ na teknụzụ nhazi njehie FEC na-eme ka nnyefe arụmọrụ dị elu na ogologo anya dị elu.
-
Nduzi okporo ígwè na-achịkwa nke ọma - mgba ọkụ Ethernet nke ụlọ ọrụ mmepụta ihe 8GX+8GE
Nduzi ụdị njikwa ụgbọ okporo ígwè klas ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, na-akwado ike gigabit 8 + ọkụ gigabit 8, nhazi mgbanwe. Ntinye ike na-adịghị agbanwe agbanwe, nhazi okpomọkụ sara mbara, ikike mgbochi eletrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50 ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Ngwaahịa a nwere obere ahụ, okpomọkụ ọrụ nke -40℃ ~75℃, klas nchekwa IP42, nke nwere oche kaadị ụgbọ okporo ígwè siri ike, nke enwere ike iji ya nke ukwuu na ọnọdụ ngwa siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ihe nlereanya ike nke ọkwa ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet 4T+24GX+8C
Nhazi ụdị ihe eji echekwa ihe na klaasị ụlọ ọrụ mmepụta ihe, mgba ọkụ Ethernet, na-akwado ọkụ 24 gigabit+Ike iji ike 8 Gigabit mee ihe +4 Ọkụ gigabit iri, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi elektrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi ụzọ akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ 1U rack ngwaahịa, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ike nke ụdị ihe nlereanya ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet 4T+24GX+24GE
Njikwa ụdị rack klaasị ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, na-akwado ọkụ gigabit 24 + ọkụ gigabit 24 + ọkụ gigabit 6, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi eletrọnik siri ike, nke dabara adaba maka ohere ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi nke akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ ngwaahịa 1U rack, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ihe nlereanya ike nke ọkwa ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet 6T+48GE
Rnjikwa ụdị ack klaasị ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, nkwado48ike gigabit +6 Ọkụ gigabit iri, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi elektrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi ụzọ akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ ngwaahịa 1U rack, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ihe nlereanya ike nke ọkwa ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet 4T+24GE+8C
Nhazi ụdị rack ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, na-akwado ike gigabit 24 +8 Gigabit reuse light +4 Ọkụ gigabit iri, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi elektrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi ụzọ akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ 1U rack ngwaahịa, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ihe nlereanya ike nke ọkwa ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet mgba ọkụ ụlọ ọrụ 4T+24GE
Rnjikwa ụdị ack klaasị ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, na-akwado ike gigabit 24 + 4Ọkụ gigabit iri, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi elektrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi ụzọ akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ 1U rack ngwaahịa, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.
-
Nduzi okporo ígwè na-achịkwa mgba ọkụ Ethernet nke ụlọ ọrụ mmepụta ihe Mgbanwe ụlọ ọrụ 4GX+24GE
Nduzi ụdị njikwa ụgbọ okporo ígwè klas ụlọ ọrụ mmepụta ihe mgba ọkụ Ethernet, na-akwado ike gigabit 24 + ọkụ gigabit 4, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi eletrọnik siri ike, nke dabara adaba maka ohere ịnweta ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50 ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Ngwaahịa a nwere obere ahụ, okpomọkụ ọrụ nke -40℃ ~75℃, klas nchekwa IP40, nke nwere oche kaadị ụgbọ okporo ígwè siri ike, nke enwere ike iji ya nke ukwuu na ọnọdụ ngwa siri ike na ụlọ ọrụ dị iche iche.
-
Ụdị ihe nlereanya ike nke ọkwa ụlọ ọrụ mmepụta ihe Ethernet mgba ọkụ ụlọ ọrụ
Njikwa ụdị rack klaasị ụlọ ọrụ mmepụta ihe, na-akwado ike gigabit 24 + ọkụ gigabit 4, nhazi mgbanwe. Ntinye ike na-enweghị atụ, nhazi okpomọkụ sara mbara, ikike mgbochi eletrọnik siri ike, nke dabara adaba maka ohere ubi ụlọ ọrụ mmepụta ihe. Ọrụ njikwa ngwaahịa gụnyere QoS, VLAN, IGMP Snooping, GVRP, Port Trunking, SNMP V1 / V2 / V3, STP / RSTP / MSTP, nhazi nke akwa atọ, wdg. Usoro netwọk mgbanaka ERPS redundant, mgbanwe njikọ netwọk na oge mgbake erughị 50ms, melite ntụkwasị obi nke netwọk ahụ. Kwado ọrụ nke nchọpụta ike anya DDM, ma kwado Console, Telnet, Web multiple management methods na ngwanrọ njikwa netwọkụ dabere na SNMP. Enwere ike iji ọkọlọtọ ngwaahịa 1U rack, okpomọkụ ọrụ nke -40℃ ~75℃, ọkwa nchekwa IP40, n'ọtụtụ ọnọdụ ngwa siri ike na nke siri ike na ụlọ ọrụ dị iche iche.












