32 Porthladdoedd EDFA
Fwdm optegol adeiledig, gall drosglwyddo rhwydwaith band eang a CATV gyda'i gilydd.
Yn mabwysiadu technoleg ffibr clad dwbl Er Yb Codoped;
Porthladdoedd mewnbwn Catv: 1 dewisol
Porthladdoedd mewnbwn Olt: 4-32 dewisol
Porthladdoedd allbwn com: 4-32 dewisol;
Pŵer allbwn optegol: cyfanswm allbwn hyd at 15W (41dBm);
Ffigur sŵn isel: <6dB pan fydd mewnbwn yn 0dBm;
Rhyngwyneb rheoli rhwydwaith perffaith, yn unol â rheolaeth rhwydwaith SNMP safonol;
Mae system rheoli tymheredd deallus yn gwneud y defnydd o bŵer yn is;

Eitem | Uned | Paramedrau techneg | Sylw | |
Lled band gweithredu | nm | 1545 - 1565 | ||
Ystod pŵer mewnbwn optegol | dBm | -3 - +10 | Ffoniodd y mwyaf:-10-+10 | |
Amser newid optegol | ms | ≤ 5 | ||
Uchafswm pŵer allbwn optegol | dBm | 41 | ||
Sefydlogrwydd pŵer allbwn | dBm | ±0.5 | ||
Ffigwr swn | dB | ≤ 6.0 | Pŵer mewnbwn optegol 0dBm, λ=1550nm | |
Colli dychwelyd | Mewnbwn | dB | ≥ 45 | |
Allbwn | dB | ≥ 45 | ||
Math Connector Optegol | CATV YN: SC/APC, PON: SC/PC NEU LC/PC COM: SC/APC NEU LC/APC | |||
Colli mewnosodiad porthladd PON i COM | ≤ 1.0 | dBm | ||
C/N | dB | ≥ 50 | Prawf cyflwr yn ôl GT/T 184-2002. | |
C/CTB | dB | ≥ 63 | ||
C/CSO | dB | ≥ 63 | ||
Foltedd cyflenwad pŵer | V | A: AC100V - 260V (50 Hz ~ 60Hz) B: DC48V (50 Hz ~ 60Hz) C: DC12V (50 Hz ~ 60Hz) | ||
Amrediad tymheredd gweithredu | °C | -10 – +42 | ||
Lleithder cymharol gweithredu uchaf | % | Uchafswm o 95% dim anwedd | ||
Lleithder cymharol storio uchaf | % | Uchafswm o 95% dim anwedd | ||
Dimensiwn | mm | 483(L)×440(W)×88(H) |
Tabl Cymharu Model a Phŵer
Model | Cyfanswmpŵer allbwn dBm | Rhif porthladdoedd allbwn | Pŵer allbwn fesul porthladd dBm | GYDAWDM |
EYA-4 -18 | 25 | 4 | 18 | 17 |
EYA-4 -19 | 26 | 4 | 19 | 18 |
EYA-4 -20 | 27 | 4 | 20 | 19 |
EYA-4 -21 | 28 | 4 | 21 | 20 |
EYA-4 -22 | 29 | 4 | 22 | 21 |
EYA-4 -23 | 30 | 4 | 23 | 22 |
EYA-4 -24 | 31 | 4 | 24 | 23 |
EYA-8 -15 | 25 | 8 | 15 | 14 |
EYA-8 -16 | 26 | 8 | 16 | 15 |
EYA-8 -17 | 27 | 8 | 17 | 16 |
EYA-8 -18 | 28 | 8 | 18 | 17 |
EYA-8 -19 | 29 | 8 | 19 | 18 |
EYA-8 -20 | 30 | 8 | 20 | 19 |
EYA-8 -21 | 31 | 8 | 21 | 20 |
EYA-8 -22 | 32 | 8 | 22 | 21 |
EYA-8 -23 | 34 | 8 | 23 | 22 |
EYA-8 -24 | 35 | 8 | 24 | 23 |
EYA-16 -15 | 29 | 16 | 15 | 14 |
EYA-16 -16 | 30 | 16 | 16 | 15 |
EYA-16 -17 | 31 | 16 | 17 | 16 |
EYA-16 -18 | 32 | 16 | 18 | 17 |
EYA-16 -19 | 33 | 16 | 19 | 18 |
EYA-16 -20 | 34 | 16 | 20 | 19 |
EYA-16 -21 | 35 | 16 | 21 | 20 |
EYA-16 -22 | 36 | 16 | 22 | 21 |
EYA-16 -23 | 37 | 16 | 23 | 22 |
EYA-16 -24 | 38 | 16 | 24 | 23 |
EYA-32 -15 | 32 | 32 | 15 | 14 |
EYA-32 -16 | 33 | 32 | 16 | 15 |
EYA-32 -17 | 34 | 32 | 17 | 16 |
EYA-32 -18 | 35 | 32 | 18 | 17 |
EYA-32 -19 | 36 | 32 | 19 | 18 |
EYA-32 -20 | 37 | 32 | 20 | 19 |
EYA-32 -21 | 38 | 32 | 21 | 20 |
EYA-32 -22 | 39 | 32 | 22 | 21 |
EYA-32 -23 | 40 | 32 | 23 | 22 |
EYA-32 -24 | 41 | 32 | 24 | 23 |
O Borth PON i Borth COM mae gennych golled mewnosod 1dBm a 1310nm a 1490nm.
Cais
Rhwydwaith ymhelaethu ffibr 1550 modd sengl
Rhwydwaith FTTH
Rhwydwaith CATV
Rhwydwaith cefnffyrdd pellter hir.FTTx PON, tonfedd gweithio uchaf: 1529.16 ~ 1563.86nm.
Pob math o system drosglwyddo SDH / PDH.